Sonatest Sitescan 240 Ultrasonic Flaw Detector

Original price was: $2000.Current price is: $1000.

SPECS :

SS-240 SPECIFICATION
Test Range: 5mm to 10000mm (0.2-400in) at steel velocity. Variable
in 1,2,5 sequence, or continuously in 1mm (0.05in)
increments. Also from 1 to 5000 (µs).
Velocity: 1000 to 9999m/s continuously variable.
Probe Zero: 0 to 999.999 µs, continuously variable.
Delay: Calibrated delay from 0-10000mm in 0.05mm steps at
steel velocity (0-200in. in 0.05in steps).

Category: Tag:
Compare
Description

Sonatest Sitescan 240 Ultrasonic Flaw Detector

The SITESCAN 240 digital ultrasonic flaw detector builds on the strengths of the well proven Sitescan 230 Instrument, updated to provide new features and enhanced performance in a lightweight, rugged, waterproof package.

Sonatest Sitescan 240 Ultrasonic Flaw Detector

SPECS :

SS-240 SPECIFICATION
Test Range: 5mm to 10000mm (0.2-400in) at steel velocity. Variable
in 1,2,5 sequence, or continuously in 1mm (0.05in)
increments. Also from 1 to 5000 (µs).
Velocity: 1000 to 9999m/s continuously variable.
Probe Zero: 0 to 999.999 µs, continuously variable.
Delay: Calibrated delay from 0-10000mm in 0.05mm steps at
steel velocity (0-200in. in 0.05in steps).
Gain: 0 to 110dB. Adjustable in 0.5, 2, 6, 14 and 20 dB steps.
Direct access to gain control at all times.
Test Modes: Pulse echo and transmit/receive.
Pulser: Square wave pulser, 185V peak amplitude Pulse width
40-250ns linked to frequency selection.
P.R.F.: Selectable 35,63,150,250,500 and 1000 Hz
Video
Update Rate: 60Hz (NTSC Mode); 50 Hz (PAL Mode).
Rectification: Full wave, positive or negative halfwave and unrectified rf
Frequency
Range: 4 Narrow Bands centred at 1MHz, 2MHz, 5MHz, and 10
MHz. Broad Band at 1.5 to 15 MHz (-6dB).
System
Linearity: Vertical ±1% Full Screen Height (FSH) Amplifier
Accuracy ±0.1dB. Horizontal ± 0.4% Full Screen Width
(FSW).
Reject: 50% suppressive reject. LED warning light when
selected.
Units: Metric (mm), Inch (in), or Time (µs).
Display: A colour display, active area being 320 x 234 pixels,
102.72 mm wide by 74.76 mm high. The graticule areas
is 250 + 5 pixels by 200 pixels, 80.25 + 1.6 by 63.8 mm.
The LCD, the active area is 360 x 240 pixels, 96.0 mm
wide by 72.00 mm. The graticule area is 250+5 pixels by
200 pixels, 75.0 + 1.5 by 60 mm.
Gate Monitor: Two fully independent gates for echo monitoring and
thickness measurement. Start and width adjustable over
full range of unit, amplitude variable from 0 to 100% FSH.
Bar presentation. Positive or negative triggering for each
gate
Measurement Modes:
Mode 1: Signal monitor
Mode 2: Depth and amplitude of first signal in gate.
Mode 3: Echo to echo distance measurement. (single gate)
Mode 4: Trigonometric display of beam path, surface distance and
depth of indication.
Mode 5: T-Min mode for holding minimum thickness reading.
Resolution to 0.01mm (0.001in) for distance
measurement, or 1% FSH for amplitude measurement.
Large display of measurement at top of A-Scan display.
Measurement mode.
Gate Expansion: Expands range to width of Gate 1.
A-Scan Memory: Maximum of 100 waveforms stored with complete panel
settings. Waveforms may be recalled on display, printed
or transferred via RS232 serial interface.
Panel Memory: 20 stores for retaining calibrations
Thickness
Logging: Storage for 2000 thickness readings configured into
Block/ Location/Number. Calibration settings stored with
each Block. Maximum number of Blocks is 14. Unlimited
Location/Number values, maximum combination of 2000
readings. Readings may be reviewed, edited and printed
as required.
DAC: DAC curves may be entered and digitally drawn on the
display. Reference, -6dB, -12 dB, -14dB curves may be
selected. DAC curve selected acts as gate for alarm
outputs and height measurement in DAC +dB. DAC
parameters stored with Panel Memory. Curves available
for ASME and JIS Codes.
AWS: Built in Software for evaluation of defect indications in
accordance with AWS standards
TCG: Time Corrected Gain, also known as Swept Gain. 40dB
dynamic range greater than 30dB per Microsecond and
up to 10 points may be used, setting all signals initially to
80% Full Screen Height.
Auto-Cal: Provides Automatic calibration from two echoes.
Video: Composite video selectable between NTSC and PAL.
Clock: Sets time and date.
Reference
Waveform: This menu displays a waveform from one of the A-Log
stores as a reference or fingerprint display in a colour
different from the active display highlighting differences
from the reference.
Notes: Alphanumeric labelling for panel and A-Log allows the
user to enter Notes for storage with A-scans.
X-Offset: Allows the surface distance to be calculated from the
front of the probe with X-offset being the distance from
the index point to the front of the probe.
Display Freeze: Freezes current A-scan image.
Peak Memory: For echodynamic pattern determination.
Keylock: Prevents accidental alteration of parameters
Help Key: For instant operator guidance on using the SITESCAN
240
Waveform
Smoothing: Gives a smooth signal envelope similar to the video
filtering in analogue equipment.
Outputs: Full bi-directional serial interface to transfer parameters,
thickness readings and waveform memories. Composite
video, full PAL or NTSC compatibility. Analogue
proportional outputs programmable to distance or
amplitude of signal in the gate.
Power: Lithium Ion battery pack 14.4V, 5.0 Ampere-hours, gives
8 hours duration from a fully charged pack. (up to 15
hours with LCD). Indication of low battery status.
Recharge time 3-4 hours
Charger: Mains input of 110 or 230 volts ac.
Transducer
Sockets: BNC or LEMO (factory option)
Environmental: To IP67
Temperature: Operating -10 to +55°C. 14 to 131° F
LCD Version: 0 to +50°C. 32 to 122° F,
-20 to +70° C. -4 to 158° F (survivable)
Storage -40 to +75° C. -40 to 167° F
Size: 255 x 145 x 145mm (10.0 x 5.7 x 5.7in)
Weight: 2.5 kg (5.5 lbs.) with Li-ion Cells.
SDMS: This software package allows the transfer of memory
storage to Windows based software packages for report
writing. Windows 95, 98 and NT operating systems.

Sonatest Sitescan 240 Ultrasonic Flaw Detector

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Sonatest Sitescan 240 Ultrasonic Flaw Detector”

Your email address will not be published. Required fields are marked *

Shipping Info

Estimated shipping times throughout North America:

Shipping Type: Standard Ground
Cost: Free
Estimated Delivery Time: Product will delivery in 4-6 business hours

Non sive caeli fulminibus dixere formaeque radiis cognati. Nabataeaque effigiem facientes phoebe orbe ponderibus postquam imagine recepta? Capacius sive sidera pluviaque effervescere terrarum. Fossae quem convexi inclusum nova tepescunt metusque illic sidera. Mare recessit hunc quin? Emicuit naturae campoque scythiam dedit habentem levius!

Pondere aequalis erat: regio caesa otia videre principio. Nullus fuerat mutastis unus mutatas imagine innabilis natus postquam.